Sync Sources
The following clock sources can be used for synchronising the Base Device
network:
- The wordclock input of any Base Device
- Any digital input on the system
- The internal clock generator of any Base Device
- An external video signal
The clock signal of an external source is conditioned by the XCPU controller
board of the connected Base Device and is then distributed on the system
as a low-jitter Base Device clock.
Generator
The clock generator integrated on the XCPU board is based on a precision
quartz crystal and can be used as a master clock for the entire studio. The standard
version provides a frequency accuracy of better than ±10 ppm, thus meeting
the requirements of AES-11, Grade 2.
Auto Sync Search
At sync-source failure, a new clock source will automatically be selected.
The change occurs smoothly and without interruption. If no appropriate sync source
is found (for example, if wrong sample rates are used), the system will change to
a Base Device internal clock generator.
A freely configurable priority list determines the order of up to eight sync sources
to be considered during auto sync search.
Synchronisation Separate from the NEXUS
An extra line allows AES devices to use their own rate regardless of the
system clock. This is accomplished by using sample-rate converters on the
inputs and the outputs. This feature is also supported by the XAF and XTF boards. |