Components
DSPs & Controller
|
download
data sheet
(179 KB)

|
XCI Communication-interface Board
Intelligent Generic Interface Board for Serial
Data Formats
- Operating-panel interface for controlling the NEXUS
- Peripheral control
- Communication with external devices
- 4 interface ports
- Supported protocols: RS 232 DCE, RS 232 DTE, RS 422
AES-15, RS 422 SMPTE/EBU, MIDI, Stage Tec protocol, Ethernet
- SD memory card slot for storing large amounts of data
|


|
The NEXUS intelligent generic
communication-interface board supplements the functionality of a NEXUS
audio network with control functions: The XCI board allows external devices to be
remote-controlled and control protocols queried. Suggested applications include the
provision of connectivity to operating panels for controlling NEXUS functions
or remote-controlling peripheral units such as power amplifiers or audio recorders.
Other protocols and/or control functions for other devices can be implemented
in addition to the pre-programmed standard functions.
All control information required by the XCI board is transferred via the fibre-optic
lines of the NEXUS network, so no additional cabling is necessary. The
control functionality is fully integrated into NEXUS, and the board can therefore
be operated from anywhere on the network.
The XCI board is shipped with a project-specific hardware configuration
and various software modules. To fulfil the requirements imposed by its universal
character, the board is equipped with a dedicated processor, memory, and
firmware. A buffer based on a lithium battery or an accumulator
preserves the user data stored to the SRAM memory even when the operating voltage
is not present for an extended time.
Both
the terminal pinout and the supported protocol are individually
configured as required by the customer.
Ports
The XCI board offers four interfaces that allow for flexible configuration
to suit a wide variety of implementations. 9-pin D-Sub interface ports are a standard
feature, and the board supports a variety of data formats (e.g. MIDI).
Applications
The range of peripheral units supported is constantly being extended.
For example, the following standard configurations can be realised (other configurations
are available on request):
›
Remote-Controlling Machines from the AURUS or CANTUS Interfaces
Denon DN-C680; Fostex D 15; Sony MDS-B5; Studer A 810,
A 820, A 812, D 730, D 731, D 780; Tascam DA 38, DA 60,
DA 78, DA 88, DA 98, MD 801; Pyramis, Sequoia, etc.
› Controlling Power Amplifiers SALZBRENNER STAGETEC
MEDIAGROUP, d&b, QSC 800, Renkus-Heinz
› Controlling NEXUS Functions High-speed DSP interface
for controlling Stage Tec controllers, operation via BFE controllers
› Data Transmission Interface for transferring project-specific
label data (on request)
Options
The XCI board is supplied with a customer-specific configuration. The
actual components vary depending on the types of interface required. (Interfaces
of different types can be mixed on a single board.)
|
| |
| Versions |
| XCI |
4 serial universal interface
ports
|
| individual configuration |
| XCI-STC |
4 serial Stage Tec controllers |
|
|
| |
| XCI03
Specifications |
| Memory |
512 kB to
2 MB SRAM, battery-backed |
| flash ROM |
| Interface types |
maximum 4 galvanically isolated
serial interface ports |
| RS 232,
RS 422, RS 485, MIDI, AURUS/- and CANTUS/NEXUS-control modul, Ethernet-Port |
| RS 232 interface – DTE/DCE |
application: e.g. machine control |
| terminals |
D-Sub terminal (9-pole), female, galvanically
isolated |
| baud rate |
38.4 KBaud (typ.), 115.2 KBaud
(max.) |
| cable length |
10 m/32.8' recommended |
RS 422/485 interface
(AES-15 compliant) |
Sample application: 9-pin protocol
compliant control of external machines |
| terminals |
D-Sub terminal (9-pole), female, galvanically
isolated |
| baud rate |
38.4 KBaud (typ.), 115.2 KBaud
(max.) |
| input level |
–7 to 12 V max. |
| I/O impedance |
120 ohm |
| cable length |
100 m/330' (max.)@110-ohm
lead, ±20% |
| MIDI interface |
application: e.g. control using
MIDI program changes |
| terminals |
D-Sub terminal (9-pole), female, galvanically
isolated |
| current range |
5 mA |
| baud rate |
31.25 kBaud |
| cable length |
5 m (max.) |
| Stage Tec
interface |
application: e.g. control using
Stage tec protocol |
| terminals |
D-Sub terminal (9-pole), female, galvanically
isolated |
| I/O voltage |
4 balanced line couples (RS422 compliant) |
| I/O impedance |
110 ohm |
| baud rate |
1 MBaud (max.) |
| cable length |
100 m |
| Ethernet port |
data rate |
10/100 Mbit |
|
|
| |
|
 |
|
Stage Tec Entwicklungsgesellschaft
für professionelle Audiotechnik mbH, D-12459 Berlin, Tabbertstr.
10
Phone: +49 30 639902-0, Fax: +49 30 639902-32,
, © 2002-2008